Home/Blog/Conductive guide
Conductive guide

Electrically Conductive Tape: Types, EMI Shielding & Selection Guide

Compare copper, aluminum, conductive fabric and non-woven tapes for EMI shielding and grounding. Brands: 3M, tesa, Nitto, Sekisui. Send model and width.

8 min read

What is electrically conductive tape

Electrically conductive tape is a pressure-sensitive tape that carries current or radio-frequency signals, not just sticks two surfaces together. It is used for EMI shielding seams, grounding straps, static discharge paths, cable shielding continuity, and electromagnetic interference reduction on enclosures, PCBs and automotive electronics.

The conductive path comes from the backing or the adhesive: metal foil backings (copper or aluminum), conductive fabric cloth, or conductive non-woven webs coated with an acrylic or silicone adhesive loaded with conductive particles.

Four common conductive tape constructions

Copper foil tape offers the highest conductivity and solderability, widely used for EMI shielding, grounding and static control on electronics. Aluminum foil tape is lighter and lower cost, used for sealing and grounding where lower current is acceptable. Conductive fabric cloth tape combines a woven conductive cloth backing with an acrylic adhesive, flexible and conformable for uneven surfaces. Conductive non-woven or foam tapes provide shielding plus cushioning where a thin bond is needed.

The right construction depends on the required shielding attenuation, contact resistance, whether the part must be soldered, the curvature of the surface, and whether corrosion or oxidation of the metal layer is a concern in the operating environment.

Four constructions compared: thickness, path and solderability

Most electrical conductive tapes on the market fall into one of four constructions, and the differences that matter are the conduction path, the thickness and whether the joint can be soldered. Copper foil tape carries the highest conductivity on a solid foil, with copper thickness typically 0.025 mm to 0.10 mm, and it can be soldered, which is why it is the standard for EMI shielding and grounding on flat faces. Aluminum foil tape is lighter and lower cost, with a 0.1 mm tinned aluminum foil grade such as 3M 1345 sold with a conductive adhesive, but it has lower conductivity and cannot be soldered.

Conductive fabric tape uses a woven cloth backing, so it conforms to uneven and curved surfaces where foil would lift; the named grades are tesa 60364 at 0.1 mm and tesa 60257 at 0.25 mm for high-temperature EMI shielding. Conductive transfer tape has no backing at all: the adhesive itself carries the current, with 3M 9707 as the XYZ version and 9703 as the z-axis-only version. Non-woven conductive tapes add shielding plus cushioning where a thin bond is needed, and their thickness varies by grade, so confirm it on the data sheet rather than assuming a standard value.

Shielding attenuation is also grade-specific, and no single decibel figure covers all four constructions, so this guide gives no shielding decibel numbers. Confirm the attenuation and the resistance target against the manufacturer data sheet for the grade in question, and trial the tape on the actual surfaces before approving it, because the resistance through a real joint depends on the surfaces, the contact pressure and how cleanly the tape is applied.

XYZ versus Z-axis: choosing the wrong direction

Buyers comparing electrically conductive tapes often trip over the same distinction: whether the tape conducts across its face, through its thickness, or both. A z-axis tape conducts only through its thickness, which keeps the current on the intended path and avoids lateral shorting between adjacent pads. An XYZ tape also conducts across the plane, so it suits larger contact areas and broad grounding. Model 9703 is z-axis only, while 9707 is XYZ with higher adhesion and is specified for EMI shielding along a bond line gap or slit at higher frequencies.

The same split appears in the tesa range. Tesa 60364 is a conductive fabric tape that conducts across its face, for EMI shielding and grounding on housings and seams. Tesa 60374 is an XYZ-directional tape whose published resistance, around 0.01 ohms per square on the Z-axis, describes conduction through its thickness, for stacked assemblies where current must cross the gap between two facing surfaces. The full comparison of the two models is in the tesa 60364 versus 60374 guide.

Choosing the wrong direction fails in two ways. A z-axis-only tape used where the job needs surface shielding gives no conductive path across the seam, so the shield stays open. An XYZ tape used between closely spaced pads can short them sideways, because it conducts across the plane as well as through the thickness. State the path the current must take, across a face or through the thickness, before naming a model, and that description points to the right tape far more reliably than the word conductive on its own.

Copper foil and aluminum foil: when each one wins

Copper foil tape and aluminum foil tape are both foil constructions, but they win on different jobs. Copper foil has the highest conductivity and can be soldered, so it leads where the job needs a continuous EMI shield, a solderable ground joint or the lowest resistance on a flat face, with copper thickness typically 0.025 mm to 0.10 mm. The copper foil tape guide covers single-sided versus double-sided foil and the conductive-adhesive question in detail.

Aluminum foil tape is the lower-cost option where the current is small and weight matters. A 0.1 mm tinned aluminum foil grade with a conductive adhesive, such as 3M 1345, covers lower-current shielding, grounding and reflective duties, and aluminum foil tape also seals HVAC ducts and joins insulation, which copper foil is rarely asked to do. Aluminum cannot be soldered, so where the joint must be soldered or the resistance must be as low as possible, copper foil is the right choice; where weight and cost dominate, aluminum is enough. The aluminum foil tape guide covers adhesive choice for indoor, outdoor and high-temperature duties.

Grounding, static discharge and conductive gaskets

Three applications account for most electrically conductive tapes bought for electronics assembly: grounding, static discharge and conductive gaskets. Grounding uses the tape as a strap or pad tying a shield or enclosure to a ground plane, where the joint must stay conductive across its face. Static discharge uses a conductive fabric or non-woven tape to give sensitive assemblies a controlled discharge path, so charge cannot build up on a device that would be damaged by a sudden spark.

A conductive gasket is a different job again: the tape sits between two metal surfaces and must conduct through its thickness while also sealing the joint, which is where double-sided copper foil tape with conductive adhesive on both sides is used, with the copper in the middle joining the two faces. For each of these three applications, name the two surfaces and their finish, whether the current runs across a face or through the thickness, and the operating temperature, because those three facts decide the construction before any brand or model is chosen.

How the four brands compare

3M makes a broad line of copper and aluminum foil tapes plus conductive cloth and non-woven tapes, commonly referenced for EMI shielding and grounding in consumer electronics. tesa supplies conductive and shielding tapes for automotive and industrial EMC applications. Nitto Denko makes copper foil and conductive fabric tapes for flexible circuits and grounding. Sekisui conductive tapes are specified in Asian electronics assembly where shielding and bonding must happen in one step.

Choosing the right conductive tape

For EMI shielding on metal enclosures, copper foil tape with conductive acrylic adhesive is the standard. For grounding a flat surface where lower cost matters, aluminum foil tape is often sufficient. For uneven or curved surfaces, conductive fabric cloth tape conforms better. For static discharge on sensitive devices, a conductive non-woven or fabric tape with controlled surface resistance is preferred.

Always specify the surface being bonded, whether the tape must be soldered, the required shielding or ground resistance, and the operating environment (indoor/outdoor, temperature range, chemicals). If a brand is already called out on the drawing, name the model so the correct equivalent can be matched.

How to request samples

When requesting conductive tape samples, include: the application (EMI shielding, grounding, static discharge), the two surfaces being bonded, required conductivity or shielding level, whether soldering is needed, roll width or die-cut dimensions, and delivery destination. If a specific model is already used (for example a 3M copper foil part or a Nitto conductive fabric tape), send the model code so the supplier can match it or propose alternatives based on the same construction.

Conductive tape models buyers ask for

When buyers ask for a conductive tape by model, the request usually names one of three formats. 3M 9707 is an XYZ conductive transfer tape, with 9703 as the z-axis-only version; 9707 carries higher adhesion and is specified for EMI shielding along a bond line gap or slit at higher frequencies. Tesa 60252 is a conductive woven tape, and Tesa 60257 is a 0.25 mm conductive woven tape for high-temperature EMI shielding.

Foil tapes are the third format: copper or tinned-copper foil with a conductive adhesive, chosen for surface shielding and grounding where a facing foil is acceptable. Confirm the foil type, the adhesive conduction direction, and whether the joint must also survive a coated or oxidised surface, then send the model, width and quantity for quotation.

Frequently asked questions

What is the difference between copper foil tape and aluminum foil tape?

Copper foil tape has higher conductivity and can be soldered, making it the standard for EMI shielding and grounding on electronics. Aluminum foil tape is lighter and lower cost but has lower conductivity and cannot be soldered. Choose copper for shielding and grounding; aluminum where weight and cost dominate.

Can conductive fabric tape replace copper foil tape?

Conductive fabric cloth tape is flexible and conformable but has lower and less consistent conductivity than solid copper foil. It suits uneven surfaces and cushioning duties; for continuous EMI shielding or solderable grounding, copper foil is preferred.

What is conductive tape used for in electronics?

Common uses are EMI shielding seams on enclosures, grounding straps, cable shielding continuity, static discharge paths on sensitive assemblies, and bonding of shielding foils or gaskets. The choice depends on whether the job needs highest conductivity, conformability, or a thin bond.

What is the difference between XYZ and Z-axis conductive tape?

An XYZ tape conducts across its face and through its thickness, while a z-axis tape conducts only through its thickness. Model 9707 is XYZ with higher adhesion, for EMI shielding along a bond line gap or slit at higher frequencies, while 9703 is z-axis only, which keeps current on the intended path and avoids lateral shorting between adjacent pads. Tesa 60374 is an XYZ-directional tape with a published resistance around 0.01 ohms per square on the Z-axis, for stacked assemblies where current must cross the gap.

What thickness do electrically conductive tapes come in?

It depends on the construction. Copper foil is typically 0.025 mm to 0.10 mm, tesa 60364 conductive fabric tape is 0.1 mm, tesa 60257 conductive woven tape is 0.25 mm for high-temperature shielding, and a 0.1 mm tinned aluminum foil grade such as 3M 1345 is sold with a conductive adhesive. Transfer tapes such as 3M 9707 and 9703 have no backing, and non-woven grades vary, so confirm the total thickness on the data sheet for the grade in question.